ebm-papst DiaForce 120 standard
ebm-papst announce DiaForce 120 standard
General:
- Fan type: Mixed-flow fan
- Rotating direction looking at rotor: Clockwise
- Airflow direction: Air outlet over struts
- Bearing system: Ball bearing
- Mounting position - shaft: Any
Features
- Tacho operating voltage UBS <= 30V
- Tacho signal low US low I sink: 2mA <= 1V + Isink x Rs
- Resistor RS 180Ohm
- Tacho signal high US high I source: 0mA <= 30V
- Maximum sink current Isink <= 4mA
- External resistor External resistor Ra from UBS to US required. All voltages measured to GND
- Tacho frequency (2 x n) / 60 666Hz @ 20.000 1/min
- Tacho isolated from motor No
- Slew rate >= 0,5V/us
Applications
- The product is for the use in sheltered rooms with limited controlled temperature. Occasionally condensed water is allowed. Direct exposure to water must be avoided. Saline ambient conditions must be avoided.
- Pollution degree 2 (according DIN EN 60664-1) It occurs only non-conductive pollution. Occassionally, temporary conductivity caused by condensation occurs.