Custom Meta Tags

Hero Banner

Main Title

Murata Power Solutions IRV300 series chassis-mount isolated DC-DC converters

Mixed Media

The IRV300 series is a 300W stand alone, system level, chassis mount isolated DC-DC converter. The converter features an ultra wide input designed to accept nominal battery voltages from 24V to 110V in a single product. The IRV300 is ideally suited for Railway applications, meeting EN50155 standard in a single package. The output voltage has a wide trim range up to +15% of Vnom, and features a constant current output profile ideally suited for high inductive/capacitive loading. They feature programmable undervoltage lock- out (PUL) to prevent deep discharge of the input batteries, remote ON/OFF control and an open collector DC output power good signal including a visual LED as standard. The IRV300 offer additional options such as “Hold Up” capability for overriding load dependent input interruptions of 10mS to 20mS not affecting the output and “ORing FET” for dual redundancy or power share incorporating droop voltage. The standard self protection features include overvoltage protection, current limit/short circuit protection, over temperature protection and ensure safe and reliable power delivery.

The IRV300 series from Murata Power Solutions is a 300W stand alone, system level, chassis mount isolated DC-DC converter.

Static HTML_2

Features/Applications

Table

Features
  • 16.8V – 160V steady state, with transient range
  • of 14.4V – 168V for 100mS
  • Output voltages of 12, 24 or 54 Volts
  • Up to 300 Watts total output power
  • Ruggedized and encased chassis-mount package
  • 7.3" x 4.6" x 1.6" (185mm x 116mm x 40mm)
  • Certified to Railway standards EN 50155 and EN
  • 50121-3-2
  • High efficiency up to 92%, typical
  • Tight Line and Load regulation
  • Low Ripple and Noise
  • Extensive self-protection shut down features,
  • including over temperature shutdown
  • Output voltage adjustable
  • Green LED Power Indicator
  • Remote On/Off and PUL
  • Optional ORing feature for redundant or parallel
  • operation with droop
  • Optional Hold-up feature
  • Operating ambient temperature range -40 to
  • +70°C (10min +85°C)

Murata PS Logo HTML

Ask an Expert Grid Box Light

Contact our product specialists

Ask an expert

Have a question? Our regional technical specialists are on hand to help.

Static HTML_1

Resources

Newsletter Signup

Subscribe to our Newsletters

Researching technology for your next application design? We can help you get project ready. Get the latest design tools and solutions, Engineers' Insight and Focus magazine sent straight to your inbox.

SUBSCRIBE